skip to main |
skip to sidebar
Apr.18 CalibrateBnd Basic FB Tested (simulation)
Calibrating average color and boundary between colors was tried previously as a composite FB ( Mar.23 Calibrate as Composite FB + FindLine) This version was hard to test via simulation using FBDK due to extra delays needed for output.
The following is a Basic FB version of calibration and has been tested using FBDK.
The FB reads N samples on-the-line, then N samples off-the-line. The steps are:
- led on (light sensor positioned over line)
- on-the-line read N samples
- led off (move so light sensor positioned off the line)
- [delay will go here]
- led on (light sensor positioned off the line)
- on-the-line read N samples
- calculate average boundary between on and off the line
Interface
Execution Control Chart (ECC)
No comments:
Post a Comment